Common Gas Boiler design of European fashion style with large-screen LCD display, touch keys, easy to operate. Common Gas Boiler can show the working andcombustion status accurately, it can smart computer control and self-inspection system. Common Gas Boiler has ultra-quiet fans, pumps, combustion system, bathroom, independent heating independent system,more adaptable.
|
L1PB18 |
L1PB20 |
L1PB24 |
L1PB26 |
L1PB28 |
L1PB30 |
L1PB32 |
L1PB36 |
L1PB40 |
1. Design of European fashion style with large-screen LCD display. It can show the working andcombustion status accurately.
2. Touch keys, easy to operate.
3. Ultra-quiet fans, pumps, combustion system, bathroom, independent heating independent system,more adaptable.
4. Smart computer control and self-inspection system.
5. Multiple automatic protections.
|
Model no |
Unit |
L1PB18 |
L1PB20 |
L1PB24 |
L1PB26 |
L1PB28 |
L1PB30 |
L1PB32 |
L1PB36 |
L1PB40 |
|
|
Gas type and pressure |
LPG |
Pa |
2800 |
||||||||
|
NG |
Pa |
1300/2000 |
|||||||||
|
Rated Heat Input |
kW |
18 |
20 |
24 |
26 |
28 |
30 |
32 |
36 |
40 |
|
|
Efficiency at ratedheat power |
% |
≧99 |
|||||||||
|
Voltage |
|
AC 220V,50Hz |
|||||||||
|
Power consumption |
W |
105.0 |
105.0 |
110.0 |
110.0 |
118.0 |
118.0 |
118.0 |
210.0 |
210.0 |
|
|
Protection Class IPrating |
|
IPX4D |
|||||||||
|
Heating mode |
Rated Heat Output |
kW |
16 |
17.9 |
21.4 |
23.2 |
25 |
26.7 |
28.5 |
32 |
35.6 |
|
Minimum Heat Input |
kW |
6.3 |
6.8 |
8.4 |
9 |
9.6 |
10.5 |
11 |
12.6 |
14 |
|
|
Minimum Heat Output |
kW |
5.4 |
5.8 |
7.1 |
7.7 |
8.2 |
8.9 |
9.4 |
10.7 |
11.9 |
|
|
Heating temperature control range |
℃ |
30~80(radiator);30~60(floor heating); |
|||||||||
|
Heating Area |
m2 |
90.0 |
100.0 |
120.0 |
130.0 |
140.0 |
150.0 |
160.0 |
180.0 |
200.0 |
|
|
Applied water pressure in heating mode |
bar |
0.5-3.0 |
|||||||||
|
Preset Pressure of Expansion Tank |
bar |
1.0 |
|||||||||
|
DHW mode |
Minimum Heat Input |
kW |
6.3 |
6.8 |
8.4 |
9 |
9.6 |
10.5 |
11 |
12.6 |
14 |
|
Minimum Heat Output |
kW |
5.4 |
5.8 |
7.1 |
7.7 |
8.2 |
8.9 |
9.4 |
10.7 |
11.9 |
|
|
DHW temperature control range |
℃ |
35~60 |
|||||||||
|
Rated hot water capacity(Δt=25K ) |
L |
7.5 |
8.3 |
10.0 |
10.8 |
11.7 |
12.5 |
13.4 |
15.0 |
16.7 |
|
|
Applied water pressure in DHW mode |
bar |
0.2-8 |
|||||||||
|
Expansion tank capacity |
L |
4.5 |
6.0 |
8.0 |
|||||||
|
Pipe joint |
Cold water inlet pipe |
inch |
G3/4 |
||||||||
|
Hot water outlet pipe |
inch |
G1/2 |
|||||||||
|
Gas inlet pipe |
inch |
G3/4 |
|||||||||
|
Air input/Exhaust Duct |
mm |
Φ60/Φ100 |
|||||||||

16kw 18kw 20kw 24kw 30kw 36kw Gas Combi Boiler for Central Heating
Wall Mounted Conventional Central Heating Gas Boiler
24kW Gas Boiler with Double Circuits
Gas Central Heating Boiler with Double Circuits
20kW 24kW 28kW Gas-fired Boiler with Double Circuits
Gas Heating Boiler with Double Circuits for Home